• General
    • Automated Measurements Overview
    • System Requirements
    • Measurement Modes and Default Settings
  • Bode Automation Interface
    • Documentation
    • Command Reference
    • Changelog
  • SCPI
    • Documentation
    • Command Reference
    • Error Handling
    • Changelog

    Show / Hide Table of Contents
    • SCPI Overview
    • Getting Connected
      • Start SCPI server
      • Setup Connection
      • Usage of NI I/O Trace to monitor the SCPI traffic
    • Command Syntax
      • Introduction to the SCPI language
      • Data Formats
      • Data Transmission Formats
      • Suffixes
    • Status & Error Handling
      • Status Register System
      • Error and Event System
      • Error Handling
    • The Trigger System & Data Sychronization
      • Trigger System
      • Select the correct trigger source for :TRIG:SING
      • Synchronization
    • Coding & Examples
      • Reading the query buffer
      • Read buffer size
      • SCPI Python examples
      • Error Handling
    • List of Abbreviations
    • SCPI Changelog

    Changelog

    This changelog lists all additions and updates to the SCPI Interface, in chronological order.

    Caution

    Breaking changes are marked as bold and no longer supported or outdated commands are marked as obsolote.

    Release Version 3.50

    • Breaking Change: Implemented mandatory locking :SYST:LOCK:REQ and unlocking :SYST:LOCK:REL functionality
    • Breaking Change: If no path information is provided when storing user- or fullrange-calibrations and the SCPI server is running locally on the PC then the calibration file will be stored in the default directory C:\ProgramData\OMICRON_Lab\BodeAnalyzer\Scpi\Calibration.
    • Breaking Change: The parameter for the log level --ll and log port --lp of the SCPI Server (SCPI runner) has been changed to --logging-level respectively --logging-port.
      • Implemented missing impedance measurement modes for Impedance Adapter (:SENS:Z:METH IADapter), S11 External Coupler (:SENS:Z:METH ECOupler), External Bride (:SENS:Z:METH EBRidge ) and Voltage Current Gain (:SENS:Z:METH VCGain) measurements
    • Impedance modes also allow result convertion to reflection mode :CALC:ZPAR:DEF REFL
    • Overworked Trigger System
    • Extended error handling
    • Allow Single Point measurements
    • Smith data types are also supported for GAINphase measurements
    • Supporting Bode 500 devices
    • Additional commands for the Bode 500 devices added to the Mass Memory System: :MMEM:CAT:CORR :MMEM:DEL:CORR

    Release Version 3.25 up to 3.25 SR2

    • Minor bug fixes

    Release Version 3.24

    • Added SCPI interface to control the Bode Automation Interface via SCPI commands sent to a localhost server. Note that this is a first experimental version offering single-channel and single-trace measurements. Only measurement data can be accessed, no graphical functions or cursor functions are available