• General
  • API Documentation
  • SCPI
    • General
    • Command Reference
    • Starting Server

    Show / Hide Table of Contents
    • General commands
      • :ABORt
      • *CLS
      • *ESE
      • *ESR
      • *IDN
      • *OPC
      • *OPC?
      • *RST
      • *SRE
      • *STB
      • *TRG
      • *TST
      • *WAI
    • Calculate subsystem
      • :CALCulate:PARameter:DEFine
      • :CALCulate[:SELected]:DATA:SDATa
      • :CALCulate[:SELected]:FORMat
      • :CALCulate[:SELected]:ZPARameter:DEFine
    • Format subsystem
      • :FORMat[:DATA]
    • Initiate subsystem
      • :INITiate[:IMMediate]
      • :INITiate:CONTinuous
    • Input subsystem
      • :INPut:ATTenuation:CH1
      • :INPut:ATTenuation:CH2
      • :INPut:ATTenuation:R
      • :INPut:ATTenuation:T
      • :INPut:GAIN:CH1
      • :INPut:GAIN:CH2
      • :INPut:GAIN:R
      • :INPut:GAIN:T
      • :INPut:IMPedance:CH1
      • :INPut:IMPedance:CH2
      • :INPut:IMPedance:R
      • :INPut:IMPedance:T
    • Mass Memory subsystem
      • :MMEMory:STORe:CORRection
      • :MMEMory:LOAD:CORRection:FULLrange
      • :MMEMory:LOAD:CORRection:USERrange
    • Output subsystem
      • :OUTPut:AOFF
    • Sense subsystem
      • :SENSe:AVERage[:STATe]
      • :SENSe:AVERage:CLEar
      • :SENSe:AVERage:COUNt
      • :SENSe:BANDwidth[:RESolution]
      • :SENSe:BWIDth[:RESolution]
      • :SENSe:CORRection:FULLrange:ACTive
      • :SENSe:CORRection:FULLrange:AVAIlable
      • :SENSe:CORRection:FULLrange:ENABle
      • :SENSe:CORRection:FULLrange:EXTPolated
      • :SENSe:CORRection:FULLrange:MULTimode
      • :SENSe:CORRection:FULLrange:LOAD[:EXEcute]
      • :SENSe:CORRection:FULLrange:OPEN[:EXEcute]
      • :SENSe:CORRection:FULLrange:SHORt[:EXEcute]
      • :SENSe:CORRection:FULLrange:THRU[:EXEcute]
      • :SENSe:CORRection:IMPedance[:INPut][:MAGNitude]
      • :SENSe:CORRection:LOAD
      • :SENSe:CORRection:SDELaytime
      • :SENSe:CORRection:USERrange:ACTive
      • :SENSe:CORRection:USERrange:AVAIlable
      • :SENSe:CORRection:USERrange:ENABle
      • :SENSe:CORRection:USERrange:MULTimode
      • :SENSe:CORRection:USERrange:LOAD[:EXEcute]
      • :SENSe:CORRection:USERrange:OPEN[:EXEcute]
      • :SENSe:CORRection:USERrange:SHORt[:EXEcute]
      • :SENSe:CORRection:USERrange:THRU[:EXEcute]
      • :SENSe:FREQuency:CENTer
      • :SENSe:FREQuency:DATA
      • :SENSe:FREQuency:SPAN
      • :SENSe:FREQuency:STARt
      • :SENSe:FREQuency:STOP
      • :SENSe:SWEep:DWELl
      • :SENSe:SWEep:POINts
      • :SENSe:SWEep:TIME[:DATA]?
      • :SENSe:SWEep:TYPE
      • :SENSe:Z:METHod
    • Service subsystem
      • :SERVice:SWEep:FREQuency:MAXimum
      • :SERVice:SWEep:FREQuency:MINimum
    • Source subsystem
      • :SOURce:POWer[:LEVel][:IMMediate][:AMPLitude]
    • Status subsystem
      • :STATus:OPERation[:EVENt]
      • :STATus:OPERation:CONDition
      • :STATus:OPERation:ENABle
      • :STATus:OPERation:NTRansition
      • :STATus:OPERation:PTRansition
      • :STATus:PRESet
      • :STATus:QUEStionable[:EVENt]
      • :STATus:QUEStionable:CONDition
      • :STATus:QUEStionable:ENABle
      • :STATus:QUEStionable:NTRansition
      • :STATus:QUEStionable:PTRansition
    • System subsystem
      • :SYSTem:ERRor[:NEXT]
      • :SYSTem:ERRor:COUNt
      • :SYSTem:PRESet
      • :SYSTem:VERSion
    • Trigger subsystem
      • :TRIGger[:SEQuence][:IMMediate]
      • :TRIGger[:SEQuence]:SINGle
      • :TRIGger[:SEQuence]:SOURce

    :SENSe:FREQuency:DATA

    Description

    Gets the measurement frequencies.

    Important

    You need to perform a measurement first. Otherwise no measurement frequency values are calculated. If you have NOT performed a measurement before calling this command, 0 is returned and a Settings conflict error is added to the Error Event Queue.

    • Query
    Syntax Response possible Errors
    :SENSe<ch>:FREQuency:DATA? <numeric>,<numeric>, ..., <numeric> Settings conflict
    Parameters accepted format description
    <ch> { 1 | empty } Currently only one channel is supported. Empty means 1 is used as default.
    Response value description
    <numeric>,<numeric>, ... <numeric> list of measurement frequencies separated by a , (the amount of elements is equal to the number of points set by :SENSe:SWEep:POINts)
    0 No frequency data available because no measurement has been performed. Additionally a settings conflict error has been added to the Error Event Queue.

    Sample usage

    Configure and start a S21 measurement.

    • C#
    • Python
    var visaSession = new TcpipSocket(VISA_RESOURCENAME);
    visaSession.RawIO.Write(":SENS:FREQ:STAR 5kHz;STOP 50kHz\n");
    visaSession.RawIO.Write(":CALC:PAR:DEF S21\n");
    visaSession.RawIO.Write(":TRIG:SING\n");
    // wait for the measurement to finish
    visaSession.RawIO.Write("*OPC?\n");
    visaSession.RawIO.ReadString();
    visaSession.RawIO.Write(":SENS:FREQ:DATA?\n");
    var frequencyValues = visaSession.RawIO.ReadString();
    visaSession.RawIO.Write(":CALC:DATA:SDAT?\n");
    var measurementValues = visaSession.RawIO.ReadString();
    

    Input:

    visaSession.write(':SENS:FREQ:STAR 5kHz;STOP 50kHz\n')
    visaSession.write(':CALC:PAR:DEF S21\n')
    visaSession.write(':TRIG:SING\n')
    visaSession.query('*OPC?\n')
    frequencyValues = visaSession.query(':SENS:FREQ:DATA?\n')
    measurementValues = visaSession.query(':CALC:DATA:SDAT?\n')
    

    Related commands

    Related commands in the Automation Interface

    MeasurementFrequencies (Gain)

    MeasurementFrequencies (Impedance)

    MeasurementFrequencies (Reflection)

    MeasurementFrequencies (Gain)

    MeasurementFrequencies (OnePort)

    MeasurementFrequencies (S11)

    MeasurementFrequencies (S21)

    MeasurementFrequencies (SeriesThru)

    MeasurementFrequencies (ShuntThru)

    Back to top Generated by DocFX