• General
  • API Documentation
  • SCPI
    • General
    • Command Reference
    • Starting Server

    Show / Hide Table of Contents
    • General commands
      • :ABORt
      • *CLS
      • *ESE
      • *ESR
      • *IDN
      • *OPC
      • *OPC?
      • *RST
      • *SRE
      • *STB
      • *TRG
      • *TST
      • *WAI
    • Calculate subsystem
      • :CALCulate:PARameter:DEFine
      • :CALCulate[:SELected]:DATA:SDATa
      • :CALCulate[:SELected]:FORMat
      • :CALCulate[:SELected]:ZPARameter:DEFine
    • Format subsystem
      • :FORMat[:DATA]
    • Initiate subsystem
      • :INITiate[:IMMediate]
      • :INITiate:CONTinuous
    • Input subsystem
      • :INPut:ATTenuation:CH1
      • :INPut:ATTenuation:CH2
      • :INPut:ATTenuation:R
      • :INPut:ATTenuation:T
      • :INPut:GAIN:CH1
      • :INPut:GAIN:CH2
      • :INPut:GAIN:R
      • :INPut:GAIN:T
      • :INPut:IMPedance:CH1
      • :INPut:IMPedance:CH2
      • :INPut:IMPedance:R
      • :INPut:IMPedance:T
    • Mass Memory subsystem
      • :MMEMory:STORe:CORRection
      • :MMEMory:LOAD:CORRection:FULLrange
      • :MMEMory:LOAD:CORRection:USERrange
    • Output subsystem
      • :OUTPut:AOFF
    • Sense subsystem
      • :SENSe:AVERage[:STATe]
      • :SENSe:AVERage:CLEar
      • :SENSe:AVERage:COUNt
      • :SENSe:BANDwidth[:RESolution]
      • :SENSe:BWIDth[:RESolution]
      • :SENSe:CORRection:FULLrange:ACTive
      • :SENSe:CORRection:FULLrange:AVAIlable
      • :SENSe:CORRection:FULLrange:ENABle
      • :SENSe:CORRection:FULLrange:EXTPolated
      • :SENSe:CORRection:FULLrange:MULTimode
      • :SENSe:CORRection:FULLrange:LOAD[:EXEcute]
      • :SENSe:CORRection:FULLrange:OPEN[:EXEcute]
      • :SENSe:CORRection:FULLrange:SHORt[:EXEcute]
      • :SENSe:CORRection:FULLrange:THRU[:EXEcute]
      • :SENSe:CORRection:IMPedance[:INPut][:MAGNitude]
      • :SENSe:CORRection:LOAD
      • :SENSe:CORRection:SDELaytime
      • :SENSe:CORRection:USERrange:ACTive
      • :SENSe:CORRection:USERrange:AVAIlable
      • :SENSe:CORRection:USERrange:ENABle
      • :SENSe:CORRection:USERrange:MULTimode
      • :SENSe:CORRection:USERrange:LOAD[:EXEcute]
      • :SENSe:CORRection:USERrange:OPEN[:EXEcute]
      • :SENSe:CORRection:USERrange:SHORt[:EXEcute]
      • :SENSe:CORRection:USERrange:THRU[:EXEcute]
      • :SENSe:FREQuency:CENTer
      • :SENSe:FREQuency:DATA
      • :SENSe:FREQuency:SPAN
      • :SENSe:FREQuency:STARt
      • :SENSe:FREQuency:STOP
      • :SENSe:SWEep:DWELl
      • :SENSe:SWEep:POINts
      • :SENSe:SWEep:TIME[:DATA]?
      • :SENSe:SWEep:TYPE
      • :SENSe:Z:METHod
    • Service subsystem
      • :SERVice:SWEep:FREQuency:MAXimum
      • :SERVice:SWEep:FREQuency:MINimum
    • Source subsystem
      • :SOURce:POWer[:LEVel][:IMMediate][:AMPLitude]
    • Status subsystem
      • :STATus:OPERation[:EVENt]
      • :STATus:OPERation:CONDition
      • :STATus:OPERation:ENABle
      • :STATus:OPERation:NTRansition
      • :STATus:OPERation:PTRansition
      • :STATus:PRESet
      • :STATus:QUEStionable[:EVENt]
      • :STATus:QUEStionable:CONDition
      • :STATus:QUEStionable:ENABle
      • :STATus:QUEStionable:NTRansition
      • :STATus:QUEStionable:PTRansition
    • System subsystem
      • :SYSTem:ERRor[:NEXT]
      • :SYSTem:ERRor:COUNt
      • :SYSTem:PRESet
      • :SYSTem:VERSion
    • Trigger subsystem
      • :TRIGger[:SEQuence][:IMMediate]
      • :TRIGger[:SEQuence]:SINGle
      • :TRIGger[:SEQuence]:SOURce

    :SENSe:CORRection:FULLrange:AVAIlable

    Description

    Gets a value indicating whether the actual full range calibration is available or not. If the calibration is available, all necessary calibration measurements have been performed and the calibration data has been calculated.

    For more information about the calibration system please refer to Calibration.

    • Query
    Syntax Response
    :SENSe<ch>:CORRection:FULLrange:AVAIlable? { 1 | 0 }
    Parameters accepted format description
    <ch> { 1 | empty } Currently only one channel is supported. Empty means 1 is used as default.
    Response value description
    { 1 | 0 } Boolean value indicating whether the Full Range Calibration is available or not.

    Options

    Options Description
    OFF | 0 Full Range Calibration is not available.
    ON | 1 Full Range Calibration is available.

    Presets

    default value
    { 1 | 0 } 0

    Sample usage

    Perform a Full Range Gain Calibration and check whether it is available.

    • C#
    • Python
    var visaSession = new TcpipSocket(VISA_RESOURCENAME);
    visaSession.RawIO.Write(":CALC:PAR:DEF S21\n");
    visaSession.RawIO.Write(":SENS:CORR:FULL:THRU\n");
    visaSession.RawIO.Write("*WAI\n"); // wait for the calibration to finish
    visaSession.RawIO.Write(":SENS:CORR:FULL:AVAI?\n");
    visaSession.RawIO.ReadString();
    
    visaSession.write(':CALC:PAR:DEF S21\n')
    visaSession.write(':SENS:CORR:FULL:THRU\n')
    visaSession.write('*WAI\n') # wait for the calibration to finish
    visaSession.query(':SENS:CORR:FULL:AVAI?\n')
    

    Related commands

    :SENSe:CORRection:FULLrange:ACTive

    :SENSe:CORRection:FULLrange:ENABle

    :SENSe:CORRection:USERrange:ACTive

    :SENSe:CORRection:USERrange:AVAIlable

    :SENSe:CORRection:USERrange:ENABle

    Related commands in the Automation Interface

    IsAvailable (Gain)

    IsAvailable (Impedance)

    IsAvailable (Mulimode)

    Back to top Generated by DocFX