• General
  • API Documentation
  • SCPI
    • General
    • Command Reference
    • Starting Server

    Show / Hide Table of Contents
    • General commands
      • :ABORt
      • *CLS
      • *ESE
      • *ESR
      • *IDN
      • *OPC
      • *OPC?
      • *RST
      • *SRE
      • *STB
      • *TRG
      • *TST
      • *WAI
    • Calculate subsystem
      • :CALCulate:PARameter:DEFine
      • :CALCulate[:SELected]:DATA:SDATa
      • :CALCulate[:SELected]:FORMat
      • :CALCulate[:SELected]:ZPARameter:DEFine
    • Format subsystem
      • :FORMat[:DATA]
    • Initiate subsystem
      • :INITiate[:IMMediate]
      • :INITiate:CONTinuous
    • Input subsystem
      • :INPut:ATTenuation:CH1
      • :INPut:ATTenuation:CH2
      • :INPut:ATTenuation:R
      • :INPut:ATTenuation:T
      • :INPut:GAIN:CH1
      • :INPut:GAIN:CH2
      • :INPut:GAIN:R
      • :INPut:GAIN:T
      • :INPut:IMPedance:CH1
      • :INPut:IMPedance:CH2
      • :INPut:IMPedance:R
      • :INPut:IMPedance:T
    • Mass Memory subsystem
      • :MMEMory:STORe:CORRection
      • :MMEMory:LOAD:CORRection:FULLrange
      • :MMEMory:LOAD:CORRection:USERrange
    • Output subsystem
      • :OUTPut:AOFF
    • Sense subsystem
      • :SENSe:AVERage[:STATe]
      • :SENSe:AVERage:CLEar
      • :SENSe:AVERage:COUNt
      • :SENSe:BANDwidth[:RESolution]
      • :SENSe:BWIDth[:RESolution]
      • :SENSe:CORRection:FULLrange:ACTive
      • :SENSe:CORRection:FULLrange:AVAIlable
      • :SENSe:CORRection:FULLrange:ENABle
      • :SENSe:CORRection:FULLrange:EXTPolated
      • :SENSe:CORRection:FULLrange:MULTimode
      • :SENSe:CORRection:FULLrange:LOAD[:EXEcute]
      • :SENSe:CORRection:FULLrange:OPEN[:EXEcute]
      • :SENSe:CORRection:FULLrange:SHORt[:EXEcute]
      • :SENSe:CORRection:FULLrange:THRU[:EXEcute]
      • :SENSe:CORRection:IMPedance[:INPut][:MAGNitude]
      • :SENSe:CORRection:LOAD
      • :SENSe:CORRection:SDELaytime
      • :SENSe:CORRection:USERrange:ACTive
      • :SENSe:CORRection:USERrange:AVAIlable
      • :SENSe:CORRection:USERrange:ENABle
      • :SENSe:CORRection:USERrange:MULTimode
      • :SENSe:CORRection:USERrange:LOAD[:EXEcute]
      • :SENSe:CORRection:USERrange:OPEN[:EXEcute]
      • :SENSe:CORRection:USERrange:SHORt[:EXEcute]
      • :SENSe:CORRection:USERrange:THRU[:EXEcute]
      • :SENSe:FREQuency:CENTer
      • :SENSe:FREQuency:DATA
      • :SENSe:FREQuency:SPAN
      • :SENSe:FREQuency:STARt
      • :SENSe:FREQuency:STOP
      • :SENSe:SWEep:DWELl
      • :SENSe:SWEep:POINts
      • :SENSe:SWEep:TIME[:DATA]?
      • :SENSe:SWEep:TYPE
      • :SENSe:Z:METHod
    • Service subsystem
      • :SERVice:SWEep:FREQuency:MAXimum
      • :SERVice:SWEep:FREQuency:MINimum
    • Source subsystem
      • :SOURce:POWer[:LEVel][:IMMediate][:AMPLitude]
    • Status subsystem
      • :STATus:OPERation[:EVENt]
      • :STATus:OPERation:CONDition
      • :STATus:OPERation:ENABle
      • :STATus:OPERation:NTRansition
      • :STATus:OPERation:PTRansition
      • :STATus:PRESet
      • :STATus:QUEStionable[:EVENt]
      • :STATus:QUEStionable:CONDition
      • :STATus:QUEStionable:ENABle
      • :STATus:QUEStionable:NTRansition
      • :STATus:QUEStionable:PTRansition
    • System subsystem
      • :SYSTem:ERRor[:NEXT]
      • :SYSTem:ERRor:COUNt
      • :SYSTem:PRESet
      • :SYSTem:VERSion
    • Trigger subsystem
      • :TRIGger[:SEQuence][:IMMediate]
      • :TRIGger[:SEQuence]:SINGle
      • :TRIGger[:SEQuence]:SOURce

    :SENSe:CORRection:IMPedance[:INPut][:MAGNitude]

    Description

    This command gets or sets the nominal input impedance Z0.

    • Command
    • Query
    Syntax Parameter
    :SENSe<ch>:CORRection:IMPedance[:INPut][:MAGNitude] <numeric>
    Parameters accepted format allowed suffixes possible Errors description
    <ch> { 1 | empty } none Undefined header Currently only one channel is supported. Empty means 1 is used as default.
    <numeric> numeric value Ohm Settings conflict The input impedance in Ohm.
    Syntax Response
    :SENSe<ch>:CORRection:IMPedance[:INPut][:MAGNitude]? <numeric>
    Parameters accepted format description
    <ch> { 1 | empty } Currently only one channel is supported. Empty means 1 is used as default.
    Response value description
    <numeric> The input impedance in Ohm
    Warning

    Only in certain measurement modes input impedance values can be changed. If setting the impedance of the selected channel is not allowed in the selected measurement mode, the command is ignored and a Settings conflict error is added to the Error Event Queue.

    Sample usage

    Set the input impedance to 50Ohm in S11 measurement.

    • C#
    • Python
    var visaSession = new TcpipSocket(VISA_RESOURCENAME);
    visaSession.RawIO.Write(":CALC:PAR:DEF S11\n");
    visaSession.RawIO.Write(":SENS:CORR:IMP 50\n");
    

    Input:

    visaSession.write(':CALC:PAR:DEF S11\n')
    visaSession.write(':SENS:CORR:IMP 50\n')
    

    Related commands in the Automation Interface