No error
Nr. | Name | Type | Desription |
---|---|---|---|
0 |
No Error | none |
this value is returned when there is no error and the error event queue is completely empty |
Command Errors
Nr. | Name | Type | Desription |
---|---|---|---|
-100 |
command error | Command Error |
generic error while trying to parse the incoming message |
-102 |
syntax error | Command Error |
unrecognized command or data type (e.g. a string was received when the device does not accept strings) |
-103 |
invalid separator | Command Error |
parser was excpecting a separator and encountered an illegal character |
-104 |
data type error | Command Error |
parser detected a data element different than the one allowed |
-108 |
parameter not allowed | Command Error |
more parameters were received than expected |
-109 |
missing parameter | Command Error |
fewer parameters were received than required |
-113 |
undefined header | Command Error |
command is undefined for this device although sintactically correct |
-120 |
numeric data error | Command Error |
given parameter could not be parsed to a numeric value |
-150 |
string data error | Command Error |
general error while trying to parse a string |
-158 |
string data not allowed | Command Error |
encountered a string data were no string data was allowed |
-170 |
expression error | Command Error |
expression error (e.g. parentheses not matching or illegal characters found) |
Execution Errors
Nr. | Name | Type | Description |
---|---|---|---|
-200 |
execution error | Execution Error |
general error while executing |
-211 |
trigger ignored | Execution Error |
triggering signal was received and recognized but was ignored (e.g. because a measurement was already running) |
-213 |
init ignored | Execution Error |
measurement initiation was ignored because another measurement was already in progress |
-221 |
settings conflict | Execution Error |
a valid command could not be executed due to the current device state |
-222 |
data out of range | Execution Error |
a given parameter exceeded the allowed range |
-224 |
illegal parameter value | Execution Error |
a given parameter was not in the list of possible options that are accepted with the entered command |
-256 |
file name not found | Execution Error |
the file name on the device media was not found |
Device Dependent Errors
Nr. | Name | Type | Description |
---|---|---|---|
-300 |
device specific error | Device Dependent Error |
general error that is device specific |
-350 |
queue overflow | Device Dependent Error |
tried to add an element to a queue but queue is already full |
Query Errors
Nr. | Name | Type | Description |
---|---|---|---|
-400 |
query error | Query Error |
general query error |
Events
Nr. | Name | Type | Description |
---|---|---|---|
-500 |
power on | Event |
off to on transition of the power source was detected |
-800 |
operation complete | Event |
all pending operations have terminated |