Changelog
Release Version 3.25
- Measurement creation also initializes default sweep settings (see Measurement Modes section for further information)
- Fixed bug #184974: Shaped level isn't applied when performing full range cal. and measurement isn't configured
- Fixed bug #191723: FresQ (resonance frequency calculation) is showing values in case of non available measurement results
- Fixed bug #211697: It is possible to load user range calibration files not matching frequency points of the related measurement
Release Version 3.24
- Added SCPI interface to control the Bode Automation Interface via SCPI commands sent to a localhost server. Note that this is a first experimental version offering single-channel and single-trace measurements. Only measurement data can be accessed, no graphical functions or cursor functions are available
- Added averaging functionality
- Added FresQ (Resonace frequency and quality factor) functionality
- Added stability margin functionality
- Fixed bug #176876: Q(Tg) result wrong in AI S11OnePort measurement
- Fixed bug #166436: Different correction values (calibration values) in BAS compared to AI in ExternalBridge measurement
- Fixed bug #182009: Shaped Level not working in Python and Excel (COM) for logarithmic sweeps
Release Version 3.23
- Fixed bug #145727: AI does not deliver results in ExternalCouplerMode (related modes: "S11 External Coupler", "Impedance Adapter" and "Impedance External Brige")
Release Version 3.22
Release Version 3.21
- Added possibility to clear shaping points and remove individual values from SourceShaping, AttenuatorShaping and BandwidthShaping
- Updated USB FTDI driver to Version 2.12.28 for Bode 100 Revision 2 devices
- General Bug Fixes
Release Version 3.20
- Breaking Change: ConfigureCustomSweep - frequencies parameter needs to be called by reference
- .NET Framework >= 4.7.1 required
- Added "Dispose" method to BodeAutomationInterface to avoid memory leaks when creating multiple instances
- Removed ManagementService
- Performance Improvements
- MeasurementImplementation, BodeAutomation. Results and Calibration Classes are now public accessible for better handling via COM
- General Bug Fixes
Release Version 3.12
- Saving a calibration that is not available throws an exception now
- Fixed bug: Saving and loading a calibration multiple times in a row resulted in an error
Release Version 3.11
- Moved OverloadResult and
Vrms to new Namespace
- Fixed Bug in COM-Event System
- Added "IsCalibrationExtrapolated" Property
- Added SetLogToUdpStream Function
- Updated Bode Automation Reference
- Internally removed ASYNC operations to enhance performance and stability
- Use of Async operation depricated
- Changed USB driver for Bode 100 Revision 1 devices from WinUSB to LibUSB
Release Version 3.0
- Initial Release Version 3.0