• General
  • API Documentation

    Show / Hide Table of Contents
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface
      • Bode100
      • BodeAutomation
      • BodeAutomationImplementation
      • Calibration
      • CalibrationValues
      • CorrectionValues
      • DeviceAddedDelegate
      • DeviceConfigurationImplementation
      • DeviceRemovedDelegate
      • FullRangeIsActiveChanged_Delegate
      • FullRangeIsAvailableChanged_Delegate
      • InternalCalibrationCallbackDelegate
      • InternalCalibrationImplementation
      • MeasurementImplementation
      • NewResultAvailableDelegate
      • Results
      • UserRangeIsActiveChanged_Delegate
      • UserRangeIsAvailableChanged_Delegate
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.DataTypes
      • Complex
      • IComplex
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.Enumerations
      • AngleUnit
      • Attenuator
      • CalibrationMultiModeToggle
      • Connection
      • ExecutionState
      • LevelUnit
      • LogLevel
      • MagnitudeUnit
      • ReceiverBandwidth
      • SourceMode
      • SweepMode
      • Termination
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.Helper
      • AutomationInterfaceHelpers
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.Interfaces
      • Attenuation
      • BodeAutomationInterface
      • BodeDevice
      • DeviceConfiguration
      • DeviceProperties
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.Interfaces.Calibration
      • FullLoadCalibrationValues
      • FullOpenCalibrationValues
      • FullShortCalibrationValues
      • FullThruCalibrationValues
      • GainCalibration
      • GainFullCalibrationValues
      • GainFullRange
      • GainUserCalibrationValues
      • GainUserRange
      • ImpedanceCalibration
      • ImpedanceFullCalibrationValues
      • ImpedanceFullRange
      • ImpedanceUserCalibrationValues
      • ImpedanceUserRange
      • InternalCalibration
      • MultiModeCalibration
      • MultiModeFullCalibrationValues
      • MultiModeFullRange
      • MultiModeUserCalibrationValues
      • MultiModeUserRange
      • UserLoadCalibrationValues
      • UserOpenCalibrationValues
      • UserShortCalibrationValues
      • UserThruCalibrationValues
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.Interfaces.Events
      • IBode100Events
      • IMeasurementEvent
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.Interfaces.Measurements
      • AdapterMeasurement
      • ExternalBridgeMeasurement
      • GainMeasurement
      • Impedance
      • OnePortMeasurement
      • Reflection
      • S11ExternalCouplerMeasurement
      • S11OnePortMeasurement
      • S21Measurement
      • SeriesThruMeasurement
      • ShuntThruMeasurement
      • Transmission
      • VoltageCurrentGainMeasurement
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.Interfaces.PortExtension
      • CableLosses
      • PortExtension
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.Interfaces.Results
      • AdmittanceResult
      • GainResults
      • ImpedanceResult
      • ReflectionResult
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.Interfaces.Results.SpecialResults
      • OverloadResult
      • Vrms
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.Interfaces.Shaping
      • AttenuatorShaping
      • BandwidthShaping
      • Shaping
      • SourceShaping
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.PortExtension
      • CableLossImpl
      • PortExtensionImpl
    • OmicronLab.VectorNetworkAnalysis.AutomationInterface.Shaping
      • AttenuatorShapingImpl
      • BandwidthShapingImpl
      • ShapingImpl
      • SourceShapingImpl

    Interface CableLosses

    Cable-losses interface.

    Namespace: OmicronLab.VectorNetworkAnalysis.AutomationInterface.Interfaces.PortExtension
    Assembly: OmicronLab.VectorNetworkAnalysis.AutomationInterface.dll (3.22.1690.0)
    Syntax
    [Guid("59AA30A6-6C8B-4959-86D3-4A678011327D")]
    [InterfaceType(ComInterfaceType.InterfaceIsDual)]
    [ComVisible(true)]
    public interface CableLosses

    Properties

    Frequencies

    Gets the frequencies holding a predefined cable-loss value.

    Declaration
    double[] Frequencies { get; }
    Property Value
    Type Description
    System.Double[]

    Losses

    Gets the cable-losses in dB per 100 meters related to the Frequencies.

    Declaration
    double[] Losses { get; }
    Property Value
    Type Description
    System.Double[]

    Methods

    Add(Double, Double)

    Adds a cable-loss value for a specified frequency.

    Declaration
    void Add(double frequency, double loss)
    Parameters
    Type Name Description
    System.Double frequency

    The frequency.

    System.Double loss

    The cable-loss in dB per 100 meters.

    Clear()

    Clears the cable-loss entries.

    Declaration
    void Clear()

    Remove(Double)

    Removes the cable-loss entry at a specified frequency.

    Declaration
    bool Remove(double frequency)
    Parameters
    Type Name Description
    System.Double frequency

    The frequency.

    Returns
    Type Description
    System.Boolean
    Back to top Generated by DocFX